Sas university edition vmware not working how to#

In this article, I’ll discuss both these features and how to use them in different environments. True, there’s a trick allowing you to do that – CPU Hot-Plug and Memory Hot-Add. I'll grab this information via SSH and monitor my array this way.Sometimes, you badly need to provide your VMware VMs with more RAM or vCPUs without shutting them down. SAS2IRCU: Utility Completed Successfully. SAS2IRCU: Command DISPLAY Completed Successfully.

Sas university edition vmware not working serial#

Read configuration has been initiated for controller 0Ĭhannel description : 1 Serial Attached SCSI LSI Corporation SAS2 IR Configuration Utility.Ĭopyright (c) 2008-2014 LSI Corporation. I was then able to use sas2ircu to display my adapter information: /opt/lsi/bin/sas2ircu 0 display Message: Operation finished successfully.

Sas university edition vmware not working install#

Install it using the following command (change path to match your datastore): esxcli software vib install -v /vmfs/volumes/Datastore/vmware-esx-sas2ircu.vib -no-sig-check

Sas university edition vmware not working update#

I found sas2ircu P20 on the Broadcom website which seems to work (as of 6.7.0 Update 1 Build 11675023):Įxtract the vmware-esx-sas2ircu.vib from this file and upload it to your ESXi host. Vmhba2 mpt2sas link-n/a sas.xx (0000:02:00.0) LSI Logic / Symbios Logic Dell 6Gbps SAS HBA /opt/lsi/storcli/storcli /c0 showĭescription = Controller 0 not. I was unable to get storcli or MegaCLI to display my H200 (crossflashed to 9211-8i in IR mode) adapter information: esxcli storage core adapter list | grep mpt

Sas university edition vmware not working driver#

(The fact that storcli is able to see the controller at all and query it tells me the driver is fine and compatible.) (I've tried from both the DCUI and SSH.) Weirdly storcli cx show help does work, only showing controller specific commands, but storcli cx show all does not. That syntax error, unexpected $end suggests something in the command parser is not right. help - gives details about a particular command. Help - lists all the commands with their usage. (c)Copyright 2018, AVAGO Technologies, All Rights Reserved. However, using another command such as "storcli /cx show alarm" does not.

sas university edition vmware not working

Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit SPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal storcli showĬLI Version = 007.0606.0000.0000 Mar 20, 2018Ĭtl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs HlthĠ LSIMegaRAIDSAS9271-8i 8 4 1 1 1 1 Msng On 1&2 Y 4 NdAtnĬtl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed (Bug in the tool?) It seems if you are specifying command arguments that contain a forward slash '/' it is ignored.įor example, "storcli show" works.

sas university edition vmware not working

This is probably a separate issue though. The MegaCLI command is also useless likely because of the same CIM issue./MegaCli -adpCount shows Controller Count: 0, which also means that the MegaRAID Storage Manager utility no longer detects ESXi hosts for management too.įinally with the storcli only some parts of it work. I saw from the VMWare hardware compatibility that our LSI RAID controller models are supported with an official driver so I don't think there is any compatibility issue. They just lack RAID monitoring and management now, so if an issue happens we just get a buzzer and LED blink, and have to reboot to the LSI WebBIOS to see what it's for to resolve it. The servers work very fine indeed, VMs are operating as normal. Looks like the CIM service just doesn't want to know though. The host has been rebooted after installing each VIB. I've updated the LSI SIMS provider to version 7.6 (30/May/2018), along with MegaCLI utility version 8-07-07, and the storcli utility version 007.0606.0000.0000 (20/Mar/2018). (Such as the GPU, Ethernet controllers, and Thunderbolt controllers.) Now though all sorts of hardware is showing up that isn't even storage related. In the web UI typically we'd only see elements listed for the Avago/LSI hardware RAID here, with a clear indicator of its overall health, each logical volume's health, and each physical disk's health. Yesterday 2 of our ESXi hosts were updated from 6.5 to 6.7 (build 8169922), though after doing this we noticed a few quirks when trying to access the storage hardware monitoring.